The FC-42-AB Plus Feeder Cube® is a Dual Feeder control, housed in a NEMA-1 enclosure. In addition to the dual FC-40 feeder controls, it also includes an Air Blow (AB) controller for multi-lane feeder bowl applications to blow excess parts on a lane back into bowl. Input Voltage is 120 VAC, 50/60 Hz. Unit A is fused for 10A; Unit B is fused for 5A.
Unit of Measure
Rodix P/N |
N/A 121-000-1388 |
Model Number |
N/A FC-42-AB Plus |
Brands |
N/A Rodix |
Applications |
N/A Vibratory Feeder Bowls, Inline Feeders, and Storage Hoppers |
Number of Controls |
N/A 2 (Dual) |
AC Input Voltage |
N/A 120 VAC |
Mains Frequency |
N/A 50/60 Hz |
Output Voltage |
N/A 0 to 120 VAC |
Current Rating |
N/A Unit A - 10 A Unit B - 5 A |
Enclosure Rating |
N/A NEMA-1 |
Air Blow (AB) Installed |
N/A AB installed |
Product Certifications |
N/A None |
Country of Origin |
N/A USA |
Control Interface |
N/A Analog: Potentiometer, DIP Switch |
Output Pulse Modes |
N/A 50 Hz Mains: 100, 50, 50 reverse, 33, or 25 pps 60 Hz Mains: 120, 60, 60 reverse, 40, or 30 pps |
Auxiliary Output |
N/A Not Available |
Remote Enable ON / OFF |
N/A optional via Low Voltage DC or Relay Contact |
Remote Amplitude Control |
N/A Analog: 4-20 mA or 0-5 VDC |
Minimum and Maximum Amplitude |
N/A Adjustable via Trim Pot on Control Board |
Line Voltage Compensation (LVC) |
N/A Selectable: On or Off |
Soft Start |
N/A Adjustable, 0-6 seconds |