Print Back
The FC-95-DC Plus Feeder Cube® is a Single controller with a DC output designed for use with a motor. It can also be utilized in conjunction with sensors as it is within the FC-90 family. It is an open frame unit designed for mounting on a subpanel inside an enclosure. Input voltage is 120 VAC, 50/60 Hz. Output voltage is 0-90 VDC or 0-130 VDC. Fused for 10 amps.
Unit of Measure

Specifications

Rodix P/N

N/A 121-000-8817

Model Number

N/A FC-95-DC Plus

Brands

N/A Rodix

Applications

N/A Brushed DC Motor for Conveyor or Step Feeder

Number of Controls

N/A 1 (Single)

Part Sensing

N/A 1 (Single) Sensing

Package Type

N/A Open Frame, w/ Control

Enclosure Rating

N/A None (Open Frame)

AC Input Voltage

N/A 120 VAC

Mains Frequency

N/A 50/60 Hz

Output Voltage

N/A 0 to 90 VDC0 to 130 VDC

Current Rating

N/A 10A

Output (DC)

N/A true

Product Certifications

N/A None

Country of Origin

N/A USA

Control Functions

Control Interface

N/A Analog: Potentiometer, DIP Switch

Output Pulse Modes

N/A 50 Hz Mains: 100, 50, 50 reverse, 33, or 25 pps 60 Hz Mains: 120, 60, 60 reverse, 40, or 30 pps

Vibration Sensing (Constant Feed Rate - CFR)

N/A Optional, CFR sensor P/N 123-000-0170 not included

Sensor Input (Optical, Proximity)

N/A PNP or NPN, 12 VDC

Auxiliary Output

N/A 12 VDC at 50 mA

Remote Enable ON / OFF

N/A optional via Low Voltage DC or Relay Contact

Remote Amplitude Control

N/A Analog: 4-20 mA or 0-5 VDC

Minimum and Maximum Amplitude

N/A Adjustable via Trim Pot on Control Board

Line Voltage Compensation (LVC)

N/A Selectable: On or Off

Time Delays ON / OFF

N/A Adjustable, 0-12 seconds

Soft Start

N/A Adjustable, 0-6 seconds

Accessories

Accessories

N/A 111-000-0031, Fiber Optic Cable, Glass, 36", straight ends ($70.00)
111-000-0500, Banner Minibeam Fiber Optic Sensor ($158.00)
123-000-0227, Relay Output Kit, 12 VDC, for 90+ and 200 Series Controls ($25.00)