The FC-95-DC Plus Feeder Cube® is a Single controller with a DC output designed for use with a motor. It can also be utilized in conjunction with sensors as it is within the FC-90 family. It is an open frame unit designed for mounting on a subpanel inside an enclosure. Input voltage is 120 VAC, 50/60 Hz. Output voltage is 0-90 VDC or 0-130 VDC. Fused for 10 amps.
Unit of Measure
Rodix P/N |
N/A 121-000-8817 |
Model Number |
N/A FC-95-DC Plus |
Brands |
N/A Rodix |
Applications |
N/A Brushed DC Motor for Conveyor or Step Feeder |
Number of Controls |
N/A 1 (Single) |
Part Sensing |
N/A 1 (Single) Sensing |
Package Type |
N/A Open Frame, w/ Control |
Enclosure Rating |
N/A None (Open Frame) |
AC Input Voltage |
N/A 120 VAC |
Mains Frequency |
N/A 50/60 Hz |
Output Voltage |
N/A 0 to 90 VDC0 to 130 VDC |
Current Rating |
N/A 10A |
Output (DC) |
N/A true |
Product Certifications |
N/A None |
Country of Origin |
N/A USA |
Control Interface |
N/A Analog: Potentiometer, DIP Switch |
Output Pulse Modes |
N/A 50 Hz Mains: 100, 50, 50 reverse, 33, or 25 pps 60 Hz Mains: 120, 60, 60 reverse, 40, or 30 pps |
Vibration Sensing (Constant Feed Rate - CFR) |
N/A Optional, CFR sensor P/N 123-000-0170 not included |
Sensor Input (Optical, Proximity) |
N/A PNP or NPN, 12 VDC |
Auxiliary Output |
N/A 12 VDC at 50 mA |
Remote Enable ON / OFF |
N/A optional via Low Voltage DC or Relay Contact |
Remote Amplitude Control |
N/A Analog: 4-20 mA or 0-5 VDC |
Minimum and Maximum Amplitude |
N/A Adjustable via Trim Pot on Control Board |
Line Voltage Compensation (LVC) |
N/A Selectable: On or Off |
Time Delays ON / OFF |
N/A Adjustable, 0-12 seconds |
Soft Start |
N/A Adjustable, 0-6 seconds |
Accessories |
N/A